Place of Origin:
China
نام تجاری:
YUYANG
گواهی:
CE
Model Number:
YY401
Attribute | Value |
---|---|
Power supply | AC 220V, 50HZ |
Total power | 2KW |
Timer: timing accuracy | < 1s/h |
Heat flux measurement range | (0-15) Kw/m² |
Heat flux meter accuracy | <± 3% |
Blackbody temperature error | ± 5 ℃ |
Exhaust speed | (2.5 ± 0.2) m/s |
Exhaust capacity | (39-85) m³/min |
Flame height | 60 ~ 120mm adjustable |
This test method measures the critical radiant flux of horizontally-mounted floor covering systems exposed to a flaming ignition source in a graded radiant heat environment within a test chamber. It can also measure the critical radiant flux for exposed attic floor cellulose insulation.
Suitable for all types of flooring materials including textile carpets, soft wood, wood, rubber and plastic flooring, and floor board spray materials. The apparatus evaluates combustion performance of flooring systems including substrates, backing materials, or any modifications that may affect test results.
درخواست خود را به طور مستقیم به ما بفرستید